Dimensions: 66cm3 (4in3), not including cable and I/O connector
Weight: 156 grams (5.5oz)
The XMAG operates within the nominal voltage range of 9-36 VDC and is qualified to RTCA/DO160E paragraph Category B requirements.
The XMAG consumes no more than 1 W of power under normal operating conditions.
Calibrated temperature range:
-55°C to 70°C
Bias stability: 200 nT
Max scale factor error: 0.2% of FS
Cross-axis misalignment: 2 mrad
Full scale measurement range: ±100,000 nT
Measurement resolution: 1 nT
The XMAG is qualified to the following DO-160E Environmental String:
[A2F2]BBB[(REE1)(HP)(U2FF1)]XWXXXXZBABCCWWMA3G33XAAC
Dimensions: 66cm3 (4in3), not including cable and I/O connector
Weight: 156 grams (5.5oz)
The XMAG operates within the nominal voltage range of 9-36 VDC and is qualified to RTCA/DO160E paragraph Category B requirements.
The XMAG consumes no more than 1 W of power under normal operating conditions.
Calibrated temperature range:
-55°C to 70°C
Bias stability: 200 nT
Max scale factor error: 0.2% of FS
Cross-axis misalignment: 2 mrad
Full scale measurement range: ±100,000 nT
Measurement resolution: 1 nT
The XMAG is qualified to the following DO-160E Environmental String:
[A2F2]BBB[(REE1)(HP)(U2FF1)]XWXXXXZBABCCWWMA3G33XAAC